Por favor, use este identificador para citar o enlazar este ítem: https://dspace.unl.edu.ec/jspui/handle/123456789/27524
Título : Resistencia a la fractura de postes de fibra de vidrio vs postes colados en la rehabilitación de dientes posteriores tratados endodónticamente. Revisión bibliográfica
Autor : Díaz López, Cecilia Mariana
Jumbo Obaco, Andrea Alejandra
Palabras clave : ODONTOLOGÍA
ENDODONCIA
DIENTE NO VITAL
PERNO MUÑÓN
Fecha de publicación : 11-jul-2023
Editorial : Loja
Resumen : Un diente tratado endodónticamente por lo general se encuentra estructuralmente debilitado por la pérdida de tejido dentario como resultado de las restauraciones anteriores, caries, y/o la preparación para el acceso a la terapia endodóntica. En consecuencia, un diente sin pulpa requiere una restauración que conserve y proteja la estructura dentaria remanente. Una de las alternativas para su tratamiento se basa principalmente en el uso de postes intraradiculares en su conducto. Con la finalidad de profundizar en el tema se analizó la resistencia a la fractura de los postes de fibra de vidrio y los postes colados utilizados en el tratamiento rehabilitador de dientes posteriores tratados endodónticamente mediante una revisión bibliográfica de 25 artículos publicados en bases de datos Pubmed, Science Direct, Google académico, Scielo, Elsevier, Medigraphic, a partir del año 2017. Los resultados muestran que ambos postes cumplieron con la norma ISO 10477 que indica que la resistencia a la fractura en Mpa (megapascales) mínima de los postes fibra es de 856 MPa y la norma ISO 22674 que corresponde a los metales es de 860 MPa. Presentando así, el 100% de los postes de fibra de vidrio una resistencia flexural de 1000 a 10999 Mpa; los de cobalto-cromo (9,1 %) de todos los postes colados, valores de resistencia de 5000 a 6999 Mpa; los de aleaciones de cobre-aluminio (36,4 %) un valor de 11000-12999 Mpa; y por encima de estos, mostrando superioridad en resistencia de todos los postes colados y fibra de vidrio, las aleaciones de níquel-cromo al reportar el 9,1 % un valor más alto de 15000-16000 Mpa. En conclusión, Los postes colados, con la aleación de níquel-cromo presentaron una mayor resistencia a la fractura (15536 Mpa) (9%) que los postes de fibra de vidrio (10251 Mpa) (28,6 %), por su parte los postes de fibra de vidrio son una opción de tratamiento biocompatible con el tejido dentario remanente al presentar un módulo de elasticidad (40 Gpa) similar al de la dentina (18 Gpa) y los postes colados poseen una alta resistencia a la fractura (15536 Mpa) , sin embargo, la gran tensión que genera en las superficies del diente debido a su alto módulo de elasticidad (205 Gpa) , hace al diente propenso a provocar fracturas radiculares
Descripción : An endodontically treated tooth is usually structurally weakened by the loss of tooth tissue that has resulted from previous restorations, caries, and preparation for access to endodontic therapy. Consequently, a pulpless tooth requires a restoration process that preserves and protects the remaining tooth structure. One of the alternatives for its treatment is mainly based on implanting intra-radicular posts in its canal. To delve deeper into the subject, we analyzed the fracture resistance of fiberglass posts and cast posts used in the rehabilitative treatment of endodontically treated posterior teeth employing a literature review of 25 articles published in PubMed, Science Direct, Google Academic, Scielo, Elsevier, Medi graphic databases, as of 2017. The results show that both posts complied with the ISO 10477 Norm, which states that the minimum fracture toughness in Mpa (megapascals) of fiber posts is 856 MPa, and the ISO 22674 standard corresponding to metals is 860 MPa. Thus, 100% of the fiberglass poles have a flexural strength of 1000 to 10999 MPa; the cobalt-chromium poles (9.1%) of all the cast poles have strength values of 5000 to 6999 MPa; the copper- aluminum alloy poles (36.4%) have a value of 11000-12999 MPa; and above these, showing superiority in strength of all the fiberglass poles, the cobalt-chromium poles (9.1%) of all the cast poles have strength values of 5000 to 6999 MPa; the copper-aluminum alloy poles (36.4%) have a value of 11000-12999 MPa; and above these, showing superiority in strength of all the cast poles and fiberglass poles; those of copper-aluminum alloys (36.4 %) a value of 11000-12999 Mpa; and above these, showing superiority in strength of all the cast poles and fiberglass, the nickel-chromium alloys by reporting 9.1 % a higher value of 15000-16000 Mpa. In conclusion, the cast poles with the nickel-chromium alloy had a higher fracture resistance (15536 Mpa) (9%) than the fiberglass poles (10251 Mpa) (28.6 %). On the other hand, the fiberglass posts are a biocompatible treatment option with the remaining dental tissue as they present a modulus of elasticity (40 Gpa) like that of dentin (18 Gpa). And the cast posts have a high resistance to fracture (15536 Mpa). However, the considerable stress generated on the tooth surfaces due to its high modulus of elasticity (205 Gpa) makes the tooth prone to cause root fractures
URI : https://dspace.unl.edu.ec/jspui/handle/123456789/27524
Aparece en las colecciones: Biblioteca A.S.H.

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
AndreaAlejandra_JumboObaco.pdf859,04 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.